[Solved]: Problem 2. (20 points) Two Alternators working in
Home / Expert Answers / Electrical Engineering / problem-2-20-points-two-alternators-working-in-parallel-supply-a-water-pump-motor-of-100kw-with-a-pa594

(Solved): Problem 2. (20 points) Two Alternators working in parallel supply a water pump motor of 100KW with a ...



Problem 2. (20 points) Two Alternators working in parallel supply a water pump motor of

100KW

with a power factor of 0.6 lagging together with an induction motor load of

150KVA

this has a power factor of

78%

. Alternator one is loaded

77KW

at

80%

power factor leading. Calculate the: a. KVA and power factor of the load b. KVA and power factor of Alternator B



We have an Answer from Expert

View Expert Answer

Expert Answer


We have an Answer from Expert

Buy This Answer $5

Place Order