We need to filter an incoming voltage signal, vin, using an active high pass filter. The specifications are: We have access to ideal operational amplifiers. All ideal op-amps have a 5 pF parasitic capacitance between any inverting input and the output. A roll-off of
40d(B)/()
decade is needed. A cut-off frequency,
f_(c)
, of 50 MHz is required. Draw the bode plot of the magnitude of the desired transfer function. (b)Draw a circuit that can accomplish this. Clearly label
v_(in )
and
v_(out )
and keep all components symbolic. Explicitly draw the 5 pF parasitic capacitance between the inverting input and the output of the amplifier. (c) Provide the component values for the above circuit.